FB8211B2-0756 Com Unit for MODBUS TCP
Item Number: FB8211B2-0756
- Interface between the I/O modules and the PCS/PLC
- Com unit for 80 analog or 184 digital channels
- Communication via MODBUS TCP
- Installation in suitable enclosures in Zone 1
- Module can be exchanged under voltage (hot swap)
- HART communication via MODBUS TCP
- Configuration via FDT 1.2 DTM
- Non-volatile memory for configuration and parameter settings
- Self configuration in redundant systems
- Permanently self-monitoring
- Outputs drive to safe state in case of failures
Damaging gasdesigned for operation in environmental conditions acc. to ISA-S71.04-1985, severity level G3
Addressing | IP address assigned via Ethernet |
Degree of protection | IEC 60529 |
EAC approval | Russia: RU C-IT.MIII06.B.00129 |
Ethernet address | IP V4 address (factory standard setting: 0.0.0.0, auto IP, DHCP) |
Shock resistance | shock type I, shock duration 11 ms, shock amplitude 15 g, number of shocks 18 |
Connection | via backplane |
Supported I/O modules | all FB remote I/O modules |
Mass | approx. 750 g |
Relative humidity | 95 % non-condensing |
Ambient temperature |
-20 … 60 В°C (-4 … 140 В°F) |
Degree of protection | IP20 (module) , a separate housing is required acc. to the system description |
HART communication | via Ethernet |
System information | The module has to be mounted in appropriate backplanes (FB92**) in Zone 1, 2, or outside hazardous areas. Observe the corresponding EC-type examination certificate. |
Connection | backplane bus |
Power dissipation | 2 W |
Connection | backplane bus |
Station connection | directly to PCS or PLC or via hubs or switches |
Storage temperature | -25 … 85 В°C (-13 … 185 В°F) |
Redundancy | via left front connector |
Vibration resistance | EN 60068-2-6 |
Supplementary information | EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. |
Fieldbus standard | IEEE 802.3 |
Fieldbus type | MODBUS TCP |
Relative humidity | EN 60068-2-56 |
Connection type | wired to Ex e terminals via backplane |
Connection | via right front connector in connection with service adapter SERV8001 |
Environmental test | EN 60068-2-14 |
Bus length | max. 100 m (Ethernet standard) |
Dimensions | 57 x 107 x 132 mm (2.2 x 4.2 x 5.2 inch) |
Number of channels per station |
max. 80 analog, max. 184 digital |
Rated voltage | 5 V DC , only in connection with the power supplies FB92** |
Damaging gas | EN 60068-2-42 |
Shock resistance | EN 60068-2-27 |
LED indication | LED green (power supply): On = operating, fast flash = cold start LED red (collective alarm): On = internal fault, flashing = no Modbus TCP connection LED yellow (operating mode): flashing 1 (1:1 ratio) = active, normal operation; flashing 2 (7:1 ratio) = active, simulation |
Electromagnetic compatibility | NE 21 |
Vibration resistance | frequency range 10 … 150 Hz; transition frequency: 57.56 Hz, amplitude/acceleration В± 0.075 mm/1 g; 10 cycles frequency range 5 … 100 Hz; transition frequency: 13.2 Hz amplitude/acceleration В± 1 mm/0.7 g; 90 minutes at each resonance |
Power consumption | 2.5 W |
EU-Type Examination Certificate | PTB 97 ATEX 1074 U
|
Transfer rate | 10 MBit/s |
Xem thêm các sản phẩm khác tại đây https://dailydiencongnghiep.com/san-pham/