712.15.100 & 732.15.100
WIKA 712.15.100 & 732.15.100 -(Diffenrental Pressure Gauge) WIKA/Germany
Applications
- Level measurements in closed tanks, particularly in cryotechnology
- Filter monitoring
- Monitoring and control of pumps
- For gaseous and liquid media that are not highly viscous
Special features
- Differential pressure measuring ranges from 0 … 80 mbar to 0 … 1725 mbar
- High working pressure (static pressure) of 50 bar
- Overpressure safety either side up to 50 bar
- Very compact design
- Optionally compact valve manifold with working pressure indication
Description
These high-quality gauges are characterised by their compact and robust design and are primarily used for level measurement on liquid gas tanks.
With 11 different measuring cells all usual tank sizes in cryotechnology are covered. As a result of the large measuring range overlap of the respective measuring cells, the gauge installed on the tank can be adjusted to match a whole variety of gases such as Ar, O2, N2 or CO2, with a full-scale deflection over a complete 270 degree sweep. The span adjustment is accessible from outside and does not affect the zero point. The mechanical display and the optional electrical output signal are calibrated simultaneously and easily.
An optional valve manifold for flange mounting with working pressure indication makes the central measurement of both level and working pressure possible in the one instrument.
The level display can be supplied with an optional, integrated 4 … 20 mA, 2-wire transmitter. Switch contacts for level and working pressure, as well as a transmitter for the working pressure can be retrofitted on site.
The standard centre distance of 37 mm between the process connections can be adapted to a custom centre distance of 31 mm or 54 mm using adapters for flange mounting.
DIFFERENTIAL PRESSURE GAUGE WIKA 712.15.100 & 732.15.100
Nominal size in mm | 100 |
Accuracy class | 2.5
Option: ■ 1.6 ■ 1.0 |
Scale ranges | Measuring cell 60 mbar: Setting range 0 … 40 mbar to 0 … 60 mbar
Measuring cell 90 mbar: Setting range 0 … 60 mbar to 0 … 90 mbar Measuring cell 120 mbar: Setting range 0 … 80 mbar to 0 … 120 mbar Measuring cell 165 mbar: Setting range 0 … 110 mbar to 0 … 165 mbar Measuring cell 240 mbar: Setting range 0 … 160 mbar to 0 … 240 mbar Measuring cell 330 mbar: Setting range 0 … 220 mbar to 0 … 330 mbar Measuring cell 480 mbar: Setting range 0 … 320 mbar to 0 … 480 mbar Measuring cell 660 mbar: Setting range 0 … 440 mbar to 0 … 660 mbar Measuring cell 975 mbar: Setting range 0 … 650 mbar to 0 … 975 mbar Measuring cell 1,350mbar: Setting range 0 … 900 mbar to 0 … 1,350 mbar Measuring cell 1,725mbar: Setting range 0 … 1,150 mbar to 0 … 1,725 mbar |
Scale | Single scale
Option: Individual scale design |
Zero point setting | By means of adjustable pointer |
Overload safety and max. working
pressure (static pressure) |
Either side max. 50 bar |
Connection location |
Lower mount (radial) |
Process connection | ■ 2 x G ¼, female, centre distance 37 mm
■ 2 x ¼ NPT, female, centre distance 37 mm others on request Option: Adapter for process connection, see page 6 |
Wetted materials | |
Measuring cell flanges | Model 712.15: Copper alloy CW614N (CuZn39Pb3)
Model 732.15: Stainless steel 316L |
Compression spring Stainless steel 1.4310 | Compression spring Stainless steel 1.4310 |
Separating diaphragm NBR | Separating diaphragm NBR |
Transmission parts Stainless steel 1.4301 and 1.4305 | Transmission parts Stainless steel 1.4301 and 1.4305 |
Non-wetted materials | |
Case Stainless steel | Case Stainless steel |
Bayonet ring Stainless steel | Bayonet ring Stainless steel |
Movement Stainless steel | Movement Stainless steel |
Dial Aluminium, white | Dial Aluminium, white |
Pointer Adjustable pointer, black aluminium | Pointer Adjustable pointer, black aluminium |
Window Polycarbonate (PC) | Window Polycarbonate (PC) |
Ingress protection per IEC/EN 60529 | IP65 |
Mounting | According to affixed symbols
⊕ high pressure, ⊖ low pressure |
Permissible temperature ranges
Non-Ex version:
Models 712.15.100 and 732.15.100 optionally with model 891.44 1) |
Ex version:
Models 712.15.100 and 732.15.100 with model 892.44 1) |
|
Ambient | -40 … +60 °C with oxygen
-40 … +80 °C |
-40 … +60 °C for temperature class T6 and T5
-40 … +80 °C for temperature class T4 |
Medium | -40 … +60 °C with oxygen
-40 … +80 °C |
-40 … +60 °C with oxygen
-40 … +60 °C for temperature class T6 and T5 -40 … +80 °C for temperature class T4 |