EDS-2008-EL-T
EDS-2008-EL-T – Switch Ethernet-Managed-8 cổng 10/100Baset(x)
Ethernet Interface
-
10/100BaseT(X) Ports (RJ45 connector)
- EDS-2008-EL: 8
EDS-2008-EL-M-ST: 7
EDS-2008-EL-M-SC: 7
Full/Half duplex mode
Auto MDI/MDI-X connection
Auto negotiation speed
- EDS-2008-EL: 8
-
100BaseFX Ports (multi-mode SC connector)
- EDS-2008-EL-M-SC: 1
-
100BaseFX Ports (multi-mode ST connector)
- EDS-2008-EL-M-ST: 1
-
Standards
- IEEE 802.3 for 10BaseT
IEEE 802.3u for 100BaseT(X) and 100BaseFX
IEEE 802.3x for flow control
IEEE 802.1p for Class of Service
- IEEE 802.3 for 10BaseT
-
Optical Fiber
-
Optical Fiber
100BaseFX | ||||
Multi-Mode | Single-Mode | |||
Fiber Cable Type | OM1 | 50/125 µm | G.652 | |
800 MHz x km | ||||
Typical Distance | 4 km | 5 km | 40 km | |
Wavelength | Typical (nm) | 1300 | 1310 | |
TX Range (nm) | 1260 to 1360 | 1280 to 1340 | ||
RX Range (nm) | 1100 to 1600 | 1100 to 1600 | ||
Optical Power | TX Range (dBm) | -10 to -20 | 0 to -5 | |
RX Range (dBm) | -3 to -32 | -3 to -34 | ||
Link Budget (dB) | 12 | 29 | ||
Dispersion Penalty (dB) | 3 | 1 |
Switch Properties
-
Processing Type
- Store and Forward
-
MAC Table Size
- 8 K
-
Packet Buffer Size
- 4 Mbits
DIP Switch Configuration
-
Ethernet Interface
- Quality of Service (QoS), Broadcast Storm Protection (BSP)
Power Parameters
-
Connection
- 1 removable 2-contact terminal block(s)
-
Input Current
- EDS-2008-EL: 0.067A @ 24 VDC
EDS-2008-EL-M-ST/EDS-2008-EL-M-SC: 0.105A @ 24 VDC
- EDS-2008-EL: 0.067A @ 24 VDC
-
Input Voltage
- 12/24/48 VDC
-
Operating Voltage
- 9.6 to 60 VDC
-
Overload Current Protection
- Supported
-
Reverse Polarity Protection
- Supported
Physical Characteristics
-
Installation
- DIN-rail mounting, Wall mounting (with optional kit)
-
Weight
- 163 g (0.36 lb)
-
Housing
- Metal
-
Dimensions
- EDS-2008-EL: 36 x 81 x 65 mm (1.4 x 3.19 x 2.56 in)
EDS-2008-EL-M-ST: 36 x 81 x 70.9 mm (1.4 x 3.19 x 2.79 in)
EDS-2008-EL-M-SC: 36 x 81 x 67.9 mm (1.4 x 3.19 x 2.67 in)
- EDS-2008-EL: 36 x 81 x 65 mm (1.4 x 3.19 x 2.56 in)
Environmental Limits
-
Ambient Relative Humidity
- 5 to 95% (non-condensing)
-
Operating Temperature
- EDS-2008-EL/EDS-2008-EL-M-SC/EDS-2008-EL-M-ST: -10 to 60°C (14 to 140°F)
EDS-2008-EL-T/EDS-2008-EL-M-SC-T/EDS-2008-EL-M-ST-T: -40 to 75°C (-40 to 167°F)
- EDS-2008-EL/EDS-2008-EL-M-SC/EDS-2008-EL-M-ST: -10 to 60°C (14 to 140°F)
-
Storage Temperature (package included)
- -40 to 85°C (-40 to 185°F)
Standards and Certifications
-
Safety
- UL 61010-2-201, EN 62368-1 (LVD)
-
EMC
- EN 55032/35
-
EMI
- CISPR 22, 32, FCC Part 15B Class A
-
EMS
- IEC 61000-4-2 ESD: Contact: 6 kV; Air: 8 kV
IEC 61000-4-3 RS: 80 MHz to 1 GHz: 20 V/m
IEC 61000-4-4 EFT: Power: 2 kV; Signal: 2 kV
IEC 61000-4-5 Surge: Power: 2 kV; Signal: 2 kV
IEC 61000-4-6 CS: 10 V
IEC 61000-4-8 PFMF
- IEC 61000-4-2 ESD: Contact: 6 kV; Air: 8 kV
-
Shock
- IEC 60068-2-27
-
Vibration
- IEC 60068-2-6
-
Freefall
- IEC 60068-2-32
MTBF
-
Time
- 3,472,660 hrs
-
Standards
- Telcordia (Bellcore), GB