WIKA PGS23.063
WIKA PGS23.063 – 63mm (Pressure Gauge with Switch Contact) hãng WIKA/Germany
Applications
- Control and regulation of processes
- Monitoring of plants and switching of circuits
- For gaseous and liquid aggressive media that are not highly viscous or crystallising, also in aggressive environments
- Chemical industry, petrochemical industry, power plants, mining, on-/offshore, environmental technology, machine building and general plant construction
Special Features
-
Up to 2 switch contacts per instrument
- Instruments with inductive contacts for use in hazardous areas
- Instruments with electronic contact for PLC applications
- Safety version S3 per EN 837
Description
Wherever the process pressure has to be indicated locally and, at the same time, circuits need to be switched, the model PGS23.063 switchGAUGE finds its use.
Switch contacts (electrical alarm contacts) make or break circuits dependent upon the pointer position of the indicating measuring instruments. The instrument pointer (actual value pointer) moves freely across the entire scale range, independent of the setting. The set pointer can be adjusted using a removable adjustment key in the window.
Switch contacts consisting of several contacts can also be set to a single set point. Contact actuation is made when the actual value pointer travels beyond or below the desired set point.
The pressure gauge is manufactured in accordance with DIN 16085 and fulfils all requirements of the relevant standards (EN 837-1) and regulations for the on-site display of the working pressure of pressure vessels.
As switch contacts, magnetic snap-action contacts, reed switches, inductive contacts and electronic contacts are available. Inductive contacts can be used in hazardous areas. For triggering programmable logic controllers (PLC), electronic contacts and reed switches can be used.
WIKA PGS23.063
Nominal size in mm | 63 |
Accuracy class | 1.6 |
Scale ranges | 0 … 4 bar [0 … 58 psi] to 0 … 400 bar [0 … 5,802 psi]
other units (e.g. psi, kPa) available or all other equivalent vacuum or combined pressure and vacuum ranges |
Scale | Single scale
Option: Dual scale |
Pressure limitation | |
Steady | 3/4 x full scale value |
Fluctuating | 2/3 x full scale value |
Short time | Full scale value |
Connection location | ■■ Lower mount (radial)
■■ Lower back mount |
Process connection |
■■ G ¼ B
■■ G ⅛ B ■■ ¼ NPT ■■ ⅛ NPT others on request |
Permissible temperature | |
Medium | +100 °C [+212 °F] maximum |
Ambient | -20 … +60 °C [-4 … 140 °F] |
Temperature effect | When the temperature of the measuring system deviates from the reference temperature (+20 °C): max. ±0.4 %/10 K of full scale value |
Case | Safety version S3 per EN 837: With solid baffle wall (Solidfront) and blow-out back |
Case filling | Without |
Wetted materials | |
Process connection, pressure element | Stainless steel 316L, option: Monel (model PGS26) |
Non-wetted materials |
|
Case, movement, bayonet ring | Stainless steel |
Dial | Aluminium, white, black lettering |
Instrument pointer | Aluminium, black |
Set pointer | Aluminium, red |
Window | Polycarbonate
Option: Laminated safety glass 2) |
Ingress protection per IEC/EN 60529 | IP54 |
Electrical connection | Cable length 2 m, facing downwards and to the right
Material: PVC others on request |
1) For hazardous areas, the permissible temperature of the contact model 831 will exclusively apply (see page 5). These must not be exceeded at the instrument either (for details see operating instructions). If necessary, measures for cooling (e.g. syphon, instrumentation valve, etc.) have to be taken.
2) For instruments for hazardous areas with contact model 831 |