PT-510-MM-SC-HV
PT-510-MM-SC-HV
NAME | TYPE | VERSION | RELEASE DATE |
---|---|---|---|
QIG for PT-510 Series
3.7 MB |
QIG | v6.1 | Aug 13, 2021 |
Datasheet for PT-510 Series
785.9 KB |
Datasheet | v1.1 | May 16, 2019 |
Tech Note: Recommended Procedure for STP Cable Grounding on Moxa’s Industrial Ethernet Switches
558.3 KB |
Tech Note | v1.0 | Feb 12, 2019 |
•
Technology |
|
Standards | IEEE 802.3 for 10BaseT IEEE 802.3u for 100BaseT(X) and 100BaseFX IEEE 802.3x for Flow Control IEEE 802.1D for Spanning Tree Protocol IEEE 802.1w for Rapid Spanning Tree Protocol IEEE 802.1D-2004 for Spanning Tree Protocol IEEE 802.1Q for VLAN Tagging IEEE 802.1p for Class of Service IEEE 802.1X for Authentication IEEE 802.3ad for Port Trunk with LACP IEEE 802.1s for Multiple Spanning Tree Protocol |
• Software Features PT-510-MM-SC-HV |
|
Management | IPv4/IPv6, SNMPv1/v2c/v3, DHCP Server/Client, DHCP Option 66/67/82, BootP, TFTP, SMTP, RARP, HTTP, HTTPS, Telnet, SNMP Inform, LLDP, Flow Control, Back Pressure Flow Control, Port Mirror, Syslog, RMON |
Filter | IGMPv1/v2, GMRP, GVRP, 802.1Q VLAN, VLAN Unaware, Port-Based VLAN, GVRP |
Redundancy Protocols | STP/RSTP, MSTP, Turbo Ring v1/v2, Turbo Chain, Link Aggregation |
Security | RADIUS, TACACS+, SSL, SSH, Port Lock |
Time Management | SNTP, NTP Server/Client, IEEE 1588v2 PTP (software-based) |
Industrial Protocols | EtherNet/IP, Modbus/TCP |
MIB | MIB-II, Ethernet-like MIB, P-BRIDGE MIB, Q-BRIDGE MIB, Bridge MIB, RSTP MIB, RMON MIB Group 1, 2, 3, 9 |
• Switch Properties PT-510-MM-SC-HV | |
Priority Queues | 4 |
Max. Number of VLANs | 64 |
VLAN ID Range | VID 1 to 4094 |
IGMP Groups | 256 |
MAC Table Size | 8 K |
Packet Buffer Size | 1 Mbit |
• Interface | |
RJ45 Ports | 10/100BaseT(X) auto negotiation speed, F/H duplex mode, and auto MDI/MDI-X connection |
Fiber Ports | 100BaseFX ports (SC/ST/LC/MTRJ connector) |
Console Port | RS-232 (RJ45) |
Alarm Contact | 1 relay output with current carrying capacity of 1 A @ 24 VDC |
•
Power Requirements |
|
Input Voltage | • 24 VDC • 48 VDC • 110/220 VDC/VAC |
Operating Voltage | • 18 to 36 V (24 VDC) • 36 to 72 V (48 VDC) • 88 to 300 VDC, 85 to 264 VAC (110/220 VDC/VAC) |
Input Current | (all ports are equipped with fiber)PT-508: • Max. 0.27 A @ 24 VDC • Max. 0.12 A @ 48 VDC • Max. 0.084/0.043 A @ 110/220 VDC • Max. 0.18/0.11 A @ 110/220 VAC PT-510: • Max. 0.39 A @ 24 VDC • Max. 0.18 A @ 48 VDC • Max. 0.10/0.052 A @ 110/220 VDC • Max. 0.234/0.148 A @ 110/220 VAC |
Overload Current Protection | Present |
Connection | 5-pin terminal blocks |
Reverse Polarity Protection | Present |
• Physical Characteristics | |
Housing | Aluminum alloy |
IP Rating | IP40 protection |
Dimensions | 80 x 160 x 110 mm (3.15 x 6.30 x 4.33 in) |
Weight | 1210 g (2.69 lb) |
Installation | DIN-rail mounting, wall mounting (with optional kit) |
• Environmental Limits | |
Operating Temperature | -40 to 85°C (-40 to 185°F), cold start requires min. of 100 VAC at -40°C |
Storage Temperature | -40 to 85°C (-40 to 185°F) |
Ambient Relative Humidity | 5 to 95% (non-condensing) |
• Standards and Certifications | |
Safety | UL 508 |
EMI | FCC Part 15 Subpart B Class A, EN 55032 Class A |
EMS | IEC 61000-4-2 ESD: Contact: 8 kV; Air: 15 kVIEC 61000-4-3 RS: 80 MHz to 1 GHz: PT-508: 20 V/m PT-510: 35 V/m IEC 61000-4-4 EFT: Power: 4 kV; Signal: 4 kV IEC 61000-4-5 Surge: Power; 4 kV; Signal: 4 kV IEC 61000-4-6 CS: 10 V IEC 61000-4-8 IEC 61000-4-11 |
Electrical Substation | IEC 61850-3, IEEE 1613 |
• MTBF (mean time between failures) | |
Time | 372,276 hrs |
Standard | Telcordia SR332 |