WIKA 232.36 & 233.36 – High Overpressure Safety WIKA/Germany
WIKA 232.36 & 233.36
Design | EN 837-1 |
Nominal size in mm | 100, 160 |
Accuracy class | 1.0 |
Scale ranges | |
Pressure limitation | Steady: end value of measuring range
Fluctuating: 0.9 x end value of measuring range Short time: Overpressure range |
Permissible temperature | Ambient: -40 … +60°C without liquid filling
-20 … +60 °C gauges with glycerine filling (233.36) Medium: +200 °C maximum without liquid filling +100 °C maximum with liquid filling (233.36) |
Temperature effect |
When the temperature of the measuring system deviates from the reference temperature (+20 °C): max. ±0.4 % / 10 K of full scale value |
Process connection |
Stainless steel 316L,
lower mount (LM) G ½ B (male), 22 mm flats |
Pressure element | Stainless steel 316L |
Movement | Stainless steel |
Dial | Aluminium, white, black lettering in measuring range, overpressure range indicated by a black sector |
Pointer | Aluminium, black |
Case | Stainless steel, with solid baffle wall (Solidfront) and blow-out back |
Window | Laminated safety glass |
Options | ■ Other process connection
■ Sealings (model 910.17, see data sheet AC 09.08) ■ Assembly on diaphragm seals see product review diaphragm seals ■ Other measuring ranges, for example -1 … 1.5 bar ■ Surface mounting lugs on the back or panel mounting flange, stainless steel ■ Ambient temperatures -40 °C: Silicone oil filling ■ Ingress protection IP 66 / IP 67 ■ Switch contacts (for NS 100 only, data sheet AC 08.01) ■ Bourdon tube pressure gauge with switch contacts,
■ Bourdon tube pressure gauge with electrical output signal, see model PGT23.1×0, data sheet PV 12.04 |