WIKA TG54
WIKA TG54 (Bimetal thermometer) WIKA/Germany
- General process instrumentation in the chemical and petrochemical industries, oil and gas industries, power generation and water/wastewater industries
- Temperature measurement in harsh and aggressive environments
- Suitable for applications with high vibrations
- Nominal sizes 63, 80, 100, 160 mm
- Robust, hermetically sealed case
- External reset for setting the reference temperature
- Dished dial (anti-parallax) for ease of reading
- Adjustable stem and dial version enables optimal process connection
The model TG54 bimetal thermometer has been developed and is manufactured in accordance with the EN 13190 standard. The thermometer meets the high requirements of the process industries.
Especially in the chemical and petrochemical, oil and gas, power engineering and shipbuilding industries, the temperature measuring instrument manufactured from stainless steel is used successfully. The robust, hermetically sealed case with IP65 ingress protection enables use with harsh external conditions and high vibration.
With a count of four different nominal sizes, an optimal matching to the available space and mounting conditions is possible.
At an easily accessible point on the back of the case, the zero point can be easily corrected.
The model TG54 meets the high requirements for resistance against aggressive media. As an option, the case, the stem and the process connection can be made from 316L.
WIKA TG54
Measuring element | Bimetal coil | ||
Nominal size in inch [mm] | ■ 63
■ 80 ■ 100 ■ 160 |
||
Connection location | ■ Back mount (axial)
■ Lower mount (radial) ■ Back mount, adjustable stem and dial |
||
Unit (scale range) | ■ °F
■ °C Option: ■ °F/°C (dual scale) ■ °C/°F (dual scale) |
||
Process connection | ■ Plain, without thread
■ G ½ B ■ ½ NPT ■ G ½ female ■ ½ NPT female ■ M20 x 1.5 ■ M24 x 1.5 female others on request |
||
Accuracy class | Class 1 per EN 13190 | ||
Working range |
|||
Continuous load (1 year) | Measuring range (EN 13190) | ||
Short time (max. 24 h) | Scale range (EN 13190) | ||
Stem diameter | ■ 6 mm
■ 8 mm |
||
Insertion length L1 | 63 … 1,000 mm
Minimum/maximum length is dependent on the measuring range and diameter (see tables from page 5 and 6) |
||
Window | Instrument glass
Option: ■ Laminated safety glass ■ Polycarbonate (shatterproof) |
||
Damping | Without
Option: With silicone oil case filling, up to max. 250 °C (at the probe) |
||
Versions (option) | ■ Oil and grease-free version
■ Silicone-oil-free version |
||
Materials | |||
Case, ring | Stainless steel 304 (option: stainless steel 316L) | ||
Stem, process connection (wetted) | Stainless steel 304 (option: stainless steel 316L) | ||
Elbow behind the case | Stainless steel 304 (option: stainless steel 316L), only with lower mount | ||
Dial | Aluminium, white, black lettering | ||
Pointer | Aluminium, black, adjustable pointer | ||
Joint | Stainless steel 304 (option: stainless steel 316L) | ||
Ingress protection IEC/EN 60529 | IP65
Option: ■ IP66 ■ IP67 ■ IP68 (continuous immersion up to 5 m) |
||
Permissible ambient temperature at case | unfilled | filled | Option |
Instrument glass | -40 … +100 °C 1) | -40 … +70 °C | -50 … +70 °C |
Laminated and polycarbonate window | -40 … +70 °C 1) | -40 … +70 °C | -50 … +70 °C |
Permissible operating pressure at the stem | max. 25 bar, static | ||
1) For ambient temperatures < 0 °C the measuring system and the window may fog up and possibly ice over. | |||
Temperature limits for storage and transport |
|||
Without liquid damping | -50 … +70 °C | ||
With liquid damping | -40 … +70 °C | ||
Overtemperature stability 2) | |||
Scale range -70 … +120 °C | 100 % overload safety of scale range | ||
Scale range 120 … 280 °C | 50 % overload safety of scale range | ||
Scale range 280 … 400 °C | max. 430 °C of scale range | ||
Scale range 400 … 600 °C | max. full scale value |