WIKA TGS 55
WIKA TGS 55 – (Bimetal thermometer with switch contact) WIKA/Germany
Applications
- Control and regulation of industrial processes
- Monitoring of plants and switching of circuits
- Chemical industry, petrochemical industry, process technology and food industry
- For aggressive media
Special features
- High reliability and long service life
- Universal application
- Case and stem from stainless steel
- Instruments with inductive contacts for use in hazardous areas
- Instruments with contacts for PLC applications
Description
Wherever the process temperature has to be indicated on-site and, at the same time, circuits need to be switched, the bimetal thermometer with switch contacts finds its use.
Switch contacts (electrical alarm contacts) make or break circuits dependent upon the pointer position of the indicating measuring instrument. The switch contacts are adjustable over the full measuring range. The instrument pointer (actual value pointer) moves freely across the entire scale range, independent of the setting.
The set pointer can be adjusted via the window using a removable adjustment key (mounted on the terminal box).
Switch contacts consisting of several contacts can also be set to a single set point. Contact actuation is made when the actual value pointer travels beyond and below the desired set point.
As switch contacts, inductive contacts and electronic contacts are available. Inductive contacts can be used in hazardous areas. For triggering programmable logic controllers (PLC), electronic contacts can be used.
WIKA TGS55
Measuring element | Bimetal coil | |
Nominal size in mm | 100 | |
Connection location | ■■ Back mount (axial)
■■ Lower mount (radial) ■■ Back mount, adjustable stem and dial |
|
Connection designs | ■■ S, Standard (threaded connection) 1)
■■ 1, Plain stem (without thread) ■■ 2, Male nut ■■ 3, Union nut ■■ 4, Compression fitting (sliding on stem) ■■ 5, Union nut and loose threaded connection |
|
Unit (scale range) | °C
Option: ■■ °F ■■ °C/°F (dual scale) |
|
Process connection | ■■ Plain, without thread
■■ G ½ B ■■ ½ NPT ■■ G ½ female ■■ ½ NPT female ■■ M20 x 1.5 ■■ M24 x 1.5 female others on request |
|
Accuracy class per DIN 16196 2) |
With single contact | With double contact |
Stem diameter 6 mm | Class 2 | Class 2 |
Stem diameter 8 mm | Class 1 | Class 2 |
Stem diameter ≥ 10 mm | Class 1 | Class 1 |
Stem diameter | 8 mm
Option: ■■ 6 mm ■■ 10 mm ■■ 12 mm |
|
Working range | ||
Continuous load (1 year) | Measuring range (DIN 16196) | |
Short time (max. 24 h) | Scale range (DIN 16196) | |
Window | Instrument glass
Option: ■■ Laminated safety glass ■■ Clear non-splintering plastic |
|
Wetted materials | ||
Stem, process connection | Stainless steel 316SS | |
Non-wetted materials | ||
Case, bayonet ring | Stainless steel 304SS (option: stainless steel 316SS) | |
Dial | Aluminium, white, black lettering | |
Pointer | Aluminium, black, adjustable pointer | |
Ingress protection per IEC/EN 60529 |
IP65
Option: IP66 |
|
Permissible temperatures 3) | ||
Ambient (at the case) | -20 … +60 °C [-4 … 140 °F] | |
Storage and transport | ||
Without liquid dampening | -50 … +70 °C [-58 … +158 °F] | |
With liquid dampening | -40 … +70 °C [-40 … +158 °F] | |
Permissible operating pressure at the stem | max. 25 bar, static | |
Electrical connection | Cable socket PA 6, black
According to VDE 0110 insulation group C/250 V Cable gland M20 x 1.5 Strain relief 6 screw terminals + PE for conductor cross-section 2.5 mm² Dimensions see page 9 others on request |
|
1) Not for version “adjustable stem and dial”
2) Adjustable stem and dial version only available in class 2 3) For hazardous areas, the permissible temperatures of the contact model 831 shall apply exclusively (for permissible temperature ranges see Seite 5). These must not be exceeded at the instrument either (for details see operating instructions). If necessary, measures for cooling (e.g. measuring point insulation) have to be taken. |