WIKA TGT73
WIKA TGT73 – (Gas-atuated thermometer with lectric output with electric output signal) WIKA/Germany
GAS-ACTUATED THERMOMETER WITH ELECTRIC OUTPUT CONTACT WIKA TGT73
- Chemical, petrochemical industry
- Oil and gas industry
- Power engineering, renewable energies
- Machine building, plant and vessel construction
- Cost-effective “2 in 1” temperature measurement
- Compact design
- Application ranges from -200 … +700 °C
- “Plug-and-play”, thus no transmitter configuration necessary
Wherever the process pressure has to be indicated on-site and, at the same time, a signal transmission to the central control or remote centre is desired, the model TGT73 intelliTHERM® can be used.
Through the combination of a mechanical measuring system and electronic signal processing, the process temperature can be read reliably, even if the voltage supply is lost.
Due to the wide variety of possible designs, the model TGT73 gas-actuated thermometers can be perfectly adapted to any process connection or location. With the adjustable stem and dial version, the case can be adjusted precisely to the desired viewing angle. With the contact bulb version (without direct contact with the medium), the temperature can be measured and controlled even when the pipe diameter is extremely small.
The electronic WIKA transmitter, integrated into the high-quality mechanical temperature measuring instrument, combines the advantages of electrical signal transmission with the advantages of a local mechanical display.
The measuring span (electrical output signal) is adjusted automatically with the mechanical display, i.e. the scale over the full scale range corresponds to 4 … 20 mA.
A 4 … 20 mA version is available for use in hazardous areas.
WIKA TGT73
Measuring element | Inert gas expansion system | |||
Nominal size in mm | ■■ 100
■■ 160 |
|||
Instrument version | ■■ Back mount (axial)
■■ Lower mount (radial) ■■ Back mount (adjustable stem and dial) ■■ Instruments with capillaries |
|||
Connection design | ■■ S Standard (male threaded connection)
■■ 1 Plain stem (without thread) ■■ 2 Male nut ■■ 3 Union nut ■■ 4 Compression fitting (sliding on stem) ■■ 5 Union nut and loose threaded connection ■■ 6 Compression fitting (can be adjusted on either capillary or spiral protective sleeve) ■■ 7 Compression fitting at the case |
|||
Unit (scale range) | °C
Option: ■■ °F ■■ °C/°F (dual scale) |
|||
Process connection |
■■ Plain, without thread
■■ G ½ B ■■ ½ NPT ■■ G ½ female ■■ ½ NPT female ■■ M20 x 1.5 ■■ M24 x 1.5 female others on request |
|||
Accuracy class | Class 1 per EN 13190
at 23 °C ±10 °C ambient temperature |
|||
Rated operating ranges and conditions | EN 13190 | |||
Stem diameter | 8 mm
Option: ■■ 6 mm ■■ 10 mm ■■ 12 mm others on request |
|||
Working range | ||||
Continuous load (1 year) | Measuring range (EN 13190) | |||
Short time (max. 24 h) | Scale range (EN 13190) | |||
Window | Laminated safety glass | |||
Contact bulb | 120 x 22 x 12 mm
Stainless steel 1.4571 |
|||
Adjustable stem and dial |
Stainless steel
Swivelling 90° 360° rotatable |
|||
Capillary | Ø 2 mm, stainless steel 1.4571, bending radius no less than 6 mm
Standard capillary: max. 60 m Capillary with spiral protective sleeve: max. 40 m Capillary with PVC coating: max. 20 m Length to customer specification Option: Armoured coating for capillary (Ø 7 mm spiral protective sleeve, flexible or PVC-coated) |
|||
Mounting types for instruments with capillary | ■■ Surface mounting flange, stainless steel
■■ Instrument mounting bracket, aluminium die-casting ■■ Panel mounting flange, stainless steel |
|||
Dampening (option) | With liquid dampening | |||
Reverse polarity protection | Yes | |||
Wetted materials | ||||
Process connection | Stainless steel 304SS | |||
Stem | Stainless steel 316SS | |||
Non-wetted materials | ||||
Case, ring | Stainless steel 304SS | |||
Dial | Aluminium, white, black lettering | |||
Pointer | Aluminium, black, adjustable pointer | |||
Ingress protection per IEC/EN 60529 | IP65 | |||
Permissible temperatures |
||||
Ambient | -20 … +60 °C [-4 … +140 °F] without/with liquid dampening | |||
Storage and transport | ||||
Without liquid dampening | -50 … +70 °C [-58 … +158 °F] | |||
With liquid dampening | -40 … +70 °C [-40 … +158 °F] | |||
Permissible operating pressure at the stem | max. 25 bar, static | |||
Electrical connection | Angular connector | |||
Power supply UB
4 … 20 mA 4 … 20 mA (Ex version) 0 … 10 V |
DC 12 ≤ UB ≤ 30 V
DC 14 ≤ UB ≤ 30 V DC 15 ≤ UB ≤ 30 V |
|||
Influence of power supply | ≤ 0.1 % of full scale/10 V | |||
Permissible residual ripple | ≤ 10 % ss | |||
Permissible max. load RA | RA ≤ (UB – 12 V)/0.02 A with RA in Ω and UB in V, however max. 600 Ω | |||
Effect of load | ≤ 0.1 % of full scale | |||
Output signal (variant I) | 4 … 20 mA, 2-wire, passive, per NAMUR NE43 | |||
Output signal (variant III) | 0 … 10 V, 3-wire | |||
Safety-related maximum values (variant II)Power supply Ui Short-circuit current Ii Power Pi Internal capacitance Ci Internal inductance Li |
max. DC 30 V max. 100 mA max. 0.72 W 12 nF negligible |
|||
Impedance at voltage output | 0.5 Ω | |||
Load capacity at voltage output | 2 … 100 kΩ | |||
Sampling rate sensor | 600 ms | |||
Linear error | ≤ 1.0 % of span (terminal method) | |||
Output signal accuracy | 0.2 % of full scale value (only electronics) | |||
Resolution | 0.15 % of full scale (10 bit resolution at 360°) | |||
Refresh rate (measuring rate) |
> 1/s | |||
Input signal, angle of rotation | 0 … 270 ∢ ° | |||
Long-term stability of electronics | < 0.3 % of full scale/a | |||
Temperature error of electronics | < 0.3 % of full scale value/10 K (in overall temperature range) | |||
Warm-up time | ≤ 5 min | |||
Electrical connection | Via angular connector, 180° rotatable, max. 1.5 mm², cable protection, M20 x 1.5
cable gland, cable outer diameter 7 … 13 mm, incl. strain relief |
|||
Designation of connection terminals dependent
on the output signal version |
Terminal
Type 1 2 3 4 5 6 |
Variant I
4 … 20 mA GND I+ reserved reserved reserved reserved |
Variant II (Ex version)
4 … 20 mA GND I+ reserved reserved reserved reserved |
Variant III
0 … 10 V GND UB+ Uout reserved reserved reserved |