Model | CY-210D | CT-110D |
---|---|---|
Power requirements for welding power supply | 220 / 230 / 240 / 380 / 400 / 415 / 440 / 460 / 480VAC -25% +10%, 50/60Hz | |
Power requirements for control power supply | 100 / 120 / 220 / 230 / 240VAC +/-20%, 50/60Hz | |
Control method | Primary or secondary current feedback type constant current control through thyristor phase control or Power requirements fluctuation compensation control type | |
Timer setting | 15 schedules | |
“SQUEEZE,” “WELD II,” “COOL II,” “WELD III,” “SLOPE II,” “HOLD,” “OFF” 00 – 99cycles | ||
“SLOPE I,” 0 – 9cycles | ||
“WELD I” “COOL I” 0 – 9cycles | “WELD I” “COOL I” 00 – 99cycles | |
Pulsation count | Switching used with Off mode 0 – 9 times | |
Current setting range | 1.0 – 80.0kA (Maximum current setting: 5.0 – 80.0kA) | |
Control speed | Secondary current feedback type constant current control 1/2 cycle (Requires toroidal coil) | |
Primary current feedback type constant current control 1cycle (Requires CT coil) | ||
Power requirements fluctuation compensation control 1cycle | ||
Current accuracy | For secondary current feedback type constant current control | |
a) ±2% max. of welding power supply voltage fluctuation +10% -15%(Accuracy based on error relative to full scale.) | ||
b) ±2% max. of resistance load fluctuation ±15%(Accuracy based on error relative to full scale.) | ||
c) ±2% max. of induction load fluctuation ±15%(Accuracy based on error relative to full scale.) | ||
Weld force output | Either 2-series control power supply voltage (1A max.) or 24VDC (0.6A max.) | |
Step up | 2 series, 9 stages | 1 series, 9 stages |
Counter 0 – 9999 | ||
Current increase ratio 50 – 200% of the set current in 1% step | ||
External input signals | INTERLOCK/COUNT RESET (dip-switch-selectable):If a closed-contact signal is input,the system waits for the power to be turned on or the count to be reset. | INTERLOCK/WELD No. SET (dip-switch-selectable):If a closed-contact signal is input, the system waits for the power to be turned on when the interlock function is selected. |
External output signals | INTERLOCK/COUNT UP (dip-switch-selectable):Outputs from 2 cycles from when the power is turned on until the power is turned off, or outputs when the counter expires (contact capacity: 110 V AC, 0.5 A) |
INTERLOCK/WELD No. ERROR (dip-switch-selectable): Output from 2 cycles before the power is turned on until the power is turned off, or when a weld-count error occurs (contact capacity: 110 V AC, 0.5 A) |
Error output |
|
|
Mass | 4.5kg |
Sản phẩm tương tự
AMADA - MIYACHI
Liên hệ để biết giá
AMADA - MIYACHI
Liên hệ để biết giá
AMADA - MIYACHI
Liên hệ để biết giá
AMADA - MIYACHI
Liên hệ để biết giá
AMADA - MIYACHI
Liên hệ để biết giá
AMADA - MIYACHI
Liên hệ để biết giá
AMADA - MIYACHI
Liên hệ để biết giá
AMADA - MIYACHI
Liên hệ để biết giá