Suffix code
Model | Code | Information | |||||
CUP- | – | Capacitive type proximity sensor | |||||
Sensing area size | 18 | M18 | |||||
30 | M30 | ||||||
Structure type | R | Round type (Brass chrome plating case) | |||||
RP | Round type (plastic case) | ||||||
Sensing distance | 8 | 8 ㎜(Only with CUP-18□-8) | |||||
15 | 15 ㎜(Only with CUP-30□-15) | ||||||
Power and Output type | N | D.C NPN output | |||||
P | D.C PNP output | ||||||
F | A.C/D.C 2 wire type(dual usage)(No polarity) | ||||||
Output state | A | Normal Open(N.O) | |||||
C | Normal Close(N.C) | ||||||
connection structure | * | No indication (Cable type) | |||||
CR | Relay connector type |
· Specification
Capacitive D.C 3 Wire type |
Model | NPN | CUP-18R-8N | CUP-18RP-8N | CUP-30R-15N | CUP-30RP-15N |
PNP | CUP-18R-8P | CUP-18RP-8P | CUP-30R-15P | CUP-30RP-15P | |
Size | M18 | M30 | |||
Shield | None shield | None shield | |||
Standard sensing object(㎜) | Iron 50 X 50 X 1 (Grounded state) | ||||
Sensing distance | 8 ㎜ (Volume variation) | 15 ㎜ (Volume variation) | |||
Setting distance | 0 ~ 6.4 mm | 0 ~ 12 mm | |||
Hysteresis | Less than 20 % of sensing distance | ||||
Response frequency | 100 Hz | ||||
Power supply voltage | 12-24Vd.c. (Usable voltage range10-30Vd.c.) | ||||
Control output | Open/Close capacitance: 200mA Max. (Resistive load), Residual voltage: Max 1.5 V | ||||
Current consumption | Max 10mA | ||||
Operation indication | Red LED | ||||
Protective circuit | Power reversely connected protective circuit, surge protective circuit and over current protective circuitare built in. |
||||
connection structure | Cable type(Standard cable length 2 m), Relay Connector type, Connector type | ||||
Material | CUP-18R/CUP-30R (Case: brass chrome plating, sensing surface:PBT resin), CUP-18RP/CUP-30RP (Case and sensing surface one body type: PBT resin) |
||||
Weight | Cable type | approx. 70g | approx. 120g | ||
Connector type | approx. 30g | approx. 80g |
Capacitive D.C/A.C dual usage 2 wire type |
Model | For A.C | CUP-18R-8F | CUP-18RP-8F | CUP-30R-15F | CUP-30RP-15F |
Size | M18 | M30 | |||
Shield | None shield | None shield | |||
Standard sensing object(㎜) | Iron 50 X 50 X 1 (Grounded state) | ||||
Sensing distance | 8 ㎜ (Volume variation) | 15 ㎜ (Volume variation) | |||
Setting distance | 0 ~ 6.4 ㎜ | 0 ~ 12 ㎜ | |||
Hysteresis | Less than 20% of sensing distance | ||||
Response frequency | 100 Hz | ||||
Power supply voltage | 20-240Va.c./d.c. (Usable voltage range 10-250Va.c./d.c.) | ||||
Control output | Open/Close capacitance : 200mA Max. (Resistive load), Residual voltage :Max 7Va.c./d.c. |
||||
Leakage Current | Max 2mA | ||||
Operation indication | Red LED | ||||
Protective circuit | Surge protective circuit built in. | ||||
connection structure | Cable type(Standard cable length 2 m), Relay Connector type, Connector type | ||||
Case | Brass(Chrome plating) | PBT resin | Brass (Chrome plating) | PBT resin | |
Material | CUP-18R/CUP-30R (Case: brass chrome plating, sensing surface: PBT resin), CUP-18RP/CUP-30RP (Case and sensing surface one body type: PBT resin) |
||||
Weight | Cable type | approx. 70g | approx. 120g | ||
Connector type | approx. 30g | approx. 80g |