FB3203B2 HART Transmitter Power Supply, Input Isolator
Ambient temperature-20 … 60 В°C (-4 … 140 В°F)
Relative humidity | 95 % non-condensing |
Input resistance | 15 Ω (terminals 5, 6)
236 Ω (terminals 1, 6) HART |
EU-Type Examination Certificate | BVS 13 ATEX E 050 X |
Transmitter supply voltage | min. 15 V at 20 mA ; 21.5 V at 4 mA |
Connection | backplane bus |
Line fault detection | can be switched on/off for each channel via configuration tool , configurable via configuration tool |
Damaging gas | EN 60068-2-42:2003 |
Relative humidity | EN 60068-2-78:2001 |
Connection | removable front connector with screw flange (accessory) wiring connection via spring terminals (0.14 … 1.5 mm2) or screw terminals (0.08 … 1.5 mm2) |
Vibration resistance | frequency range 10 … 150 Hz; transition frequency: 57.56 Hz, amplitude/acceleration В± 0.075 mm/1 g; 10 cycles frequency range 5 … 100 Hz; transition frequency: 13.2 Hz amplitude/acceleration В± 1 mm/0.7 g; 90 minutes at each resonance |
Degree of protection | IP20 (module) , a separate housing is required acc. to the system description |
LED indication | Power LED (P) green: supply Diagnostic LED (I) red: module fault , red flashing: communication error , white: fixed parameter set (parameters from com unit are ignored) , white flashing: requests parameters from com unit Status LED (1) red: line fault (lead breakage or short circuit) Status LED (2) yellow: Live Zero monitoring |
Resolution | 12 Bit (0 … 26 mA) |
Electromagnetic compatibility |
NE 21:2007 |
Shock resistance | shock type I, shock duration 11 ms, shock amplitude 15 g, number of shocks 18 |
Environmental test | EN 60068-2-14:2009 |
Number of channels | 1 |
INMETRO | Brazil: TГњV 14.1596X |
Interface | manufacturer-specific bus to standard com unit |
Refresh time | 100 ms |
HART communication | yes |
Mass | approx. 350 g |
Storage temperature | -25 … 85 В°C (-13 … 185 В°F) |
Damaging gas | designed for operation in environmental conditions acc. to ISA-S71.04-1985, severity level G3 |
HART secondary variable | no |
System information | The module has to be mounted in appropriate backplanes and housings (FB92**) in Zone 1, 2, 21, 22 or outside hazardous areas (gas or dust). Here, observe the corresponding EC-type examination certificate. |
Dimensions | 28 x 107 x 132 mm (1.1 x 4.2 x 5.2 inch) |
Coding | optional mechanical coding via front socket |
Occupied slots | 1 |
Shock resistance | EN 60068-2-27:2009 |
Supplementary information | EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. |
Connection | 2-wire transmitter (HART): supply circuit: 2/3+, 4/5- 3-wire transmitter (HART): supply circuit: 2/3+, 6- measuring circuit: 4/5+, 6- 4-wire transmitter (separately powered): measuring circuit: 4/5+, 6- HART measuring circuit: 1+, 6- |
Vibration resistance | EN 60068-2-6:2008 |
Degree of protection | IEC 60529:2000 |
Power consumption | 1.1 W |
Connection | backplane bus |
Power dissipation | 0.75 W |
Rated voltage | 12 V DC , only in connection with the power supplies FB92** |