FB4205C2 HART Output Isolator with Shutdown Input
Item Number: FB4205C2
- 4-channel
- Outputs Ex ia
- Installation in suitable enclosures in Zone 1
- Module can be exchanged under voltage (hot swap)
- Analog output module for 0/4 mA … 20 mA
- HART communication via field bus or service bus
- Simulation mode for service operations (forcing)
- Line fault detection (LFD): one LED per channel
- Permanently self-monitoring
- Output with bus-independent safety shutdown
HART secondary variableyes
Refresh time | 100 ms |
Damaging gas | designed for operation in environmental conditions acc. to ISA-S71.04-1985, severity level G3 |
HART secondary variable | no |
Mass | approx. 750 g |
Supplementary information | EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. |
HART communication | yes |
ATEX approval | BVS 12 ATEX E 015 X |
Shock resistance | EN 60068-2-27:2009 |
Interface | manufacturer-specific bus to standard com unit |
Shock resistance | shock type I, shock duration 11 ms, shock amplitude 15 g, number of shocks 18 |
Degree of protection | IEC 60529:2000 |
Power dissipation | 2.15 W |
Storage temperature | -25 … 85 В°C (-13 … 185 В°F) |
Connection | backplane bus |
Load | 750 andOmega; max. |
Environmental test | EN 60068-2-14:2009 |
Vibration resistance | EN 60068-2-6:2008 |
Connection | removable front connector with screw flange (accessory) wiring connection via spring terminals (0.14 … 1.5 mm2) or screw terminals (0.08 … 1.5 mm2) |
Ambient temperature | -20 … 60 В°C (-4 … 140 В°F) |
Relative humidity | 95 % non-condensing |
Coding | optional mechanical coding via front socket |
Rated voltage | 12 V DC , only in connection with the power supplies FB92** |
Power consumption | 3.3 W |
Damaging gas | EN 60068-2-42:2003 |
Dimensions | 57 x 107 x 132 mm (2.2 x 4.2 x 5.2 inch) |
EAC approval | Russia: RU C-IT.MIII06.B.00129 |
Occupied slots | 2 |
System information | The module has to be mounted in appropriate backplanes and housings (FB92**) in Zone 1, 2, 21, 22 or outside hazardous areas (gas or dust). Here, observe the corresponding EC-type examination certificate. |
EU-Type Examination Certificate | BVS 12 ATEX E 015 X |
Degree of protection | IP20 (module) , a separate housing is required acc. to the system description |
Connection | backplane bus |
Number of channels | 4 |
Electromagnetic compatibility | NE 21:2007 |
Relative humidity |
EN 60068-2-78:2001 |
Watchdog | within 0.5 s the device goes in safe state, e.g. after loss of communication |
Current | 0 … 25 mA short-circuit protected |
Vibration resistance | frequency range 10 … 150 Hz; transition frequency: 57.56 Hz, amplitude/acceleration В± 0.075 mm/1 g; 10 cycles frequency range 5 … 100 Hz; transition frequency: 13.2 Hz amplitude/acceleration В± 1 mm/0.7 g; 90 minutes at each resonance |
INMETRO | Brazil: TГњV 14.1595X |
HART communication | yes |
Line fault detection | can be switched on/off for each channel via configuration tool , configurable via configuration tool |
LED indication | Power LED (P) green: supply Diagnostic LED (I) red: module fault , red flashing: communication error , white: fixed parameter set (parameters from com unit are ignored) , white flashing: requests parameters from com unit Status LED (1-4) red: line fault (lead breakage or short circuit) |
Connection | terminals 1+, 2-; 3+, 4-; 5+, 6-; 7+, 8- |