Suffix code
Model | Code | Information | |||||
UP | 25 | F- | 8 | inductive type proximity sensor | |||
Sensing area size | 25 | please refer to the dimension (25 x 49 x 10 mm) | |||||
Structure type | F | Flat type | |||||
Sensing distance | 8 | 8 mm | |||||
Power and Output type | N | D.C NPN output | |||||
P | D.C PNP output | ||||||
A | A.C 2 wire type | ||||||
T | D.C 2 wire type(Polarity) | ||||||
U | D.C 2 wire type (No polarity) | ||||||
Output state | A | Normal open(N.O) | |||||
C | Normal close(N.C) | ||||||
Connection structure | * | No indication (Cable type) | |||||
CR | Relay connector |
· Specification
Inductive D.C 3 wire type/2 wire type |
Model | D.C 3 wire type | D.C 2 wire type | |||
NPN | UP25F-8N | Polarity | UP25F-8T | ||
PNP | UP25F-8P | No Polarity | UP25F-8U | ||
Size | 25 X 49 Flat type | 25 X 49 Flat type | |||
Standard sensing object(㎜) | Iron 25 X 25 X 1 | ||||
Sensing distance | 8 mm | ||||
Setting distance | 0 ~ 6.4mm | ||||
Hysteresis | Less than 10% of sensing distance | ||||
Response frequency | 200 Hz | ||||
Power supply voltage | 12 – 24 V a.c (Usable voltage range 5 – 35 V d.c) |
12 – 24 V a.c (Usable voltage range 10 – 30 V d.c) |
|||
Control output | Open/Close capacitance | 200 ㎃ max (Resistive load) | 100 ㎃ max (Resistive load) | ||
Residual voltage | Max 1.5 V | Polarity : max 3.5 V, No polarity : max 5 V | |||
Current consumption | Max 6 mA | – | |||
Leakage current | – | Max 1 mA | |||
Operation indication | Red LED | ||||
Protective circuit | Power reversely connected protective circuit, Surge protective circuit and over current protective circuit are built in. |
||||
Degree of protection | IP67 (IECstandard) | ||||
Connection structure | Cable type(Standard cable length 2m), Relay connector type | ||||
Material | Case : PBT resin, Cable holder : Polyester elastomer | ||||
Weight | Cable type | approx. 60g | approx. 60g | ||
Relay connector type | approx. 20g | approx. 20g |
Inductive A.C 2 wire type |
Model | UP25F-8A | |
Standard sensing object(㎜) | Iron 25 x 25 x 1 | |
Sensing distance | 8 mm | |
Setting distance | 0 ~ 6.4mm | |
Hysteresis | Less than 10% of sensing distance | |
Response frequency | 20 Hz | |
Power supply voltage | 100 – 240 V a.c (Usable voltage range 90 – 250 V a.c ) | |
Control output | Open/Close capacitance | 200 mA max (Resistive load) |
Residual voltage | Max 10 Va.c | |
Leakage current | Max 2.2 mA | |
Operation indication | Red LED | |
Protective circuit | Surge protective circuit built in. | |
Degree of protection | IP67 (IEC standard) | |
Connection structure | Cable type(Standard cable length 2m), Relay connector type | |
Material | Case : PBT resin, Cable holder : Polyester elastomer | |
Weight | Cable type | approx. 60g |
Relay connector type | approx. 20g |