PH0157
IFM Electronic PH0157 Flush pressure sensor
Product characteristics | |||||||||
---|---|---|---|---|---|---|---|---|---|
Output signal | analogue signal | ||||||||
Measuring range |
|
||||||||
Process connection | Clamp DN25…DN40 (1…1,5″) DIN 32676 (ISO 2852) | ||||||||
Application | |||||||||
Application | flush mountable for the food and beverage industry | ||||||||
Media | viscous media and liquids with suspended particles; liquids and gases | ||||||||
Medium temperature [°C] | -25…125; (145 max. 1h) | ||||||||
Min. bursting pressure |
|
||||||||
Pressure rating |
|
||||||||
Type of pressure | relative pressure | ||||||||
No dead space | yes | ||||||||
Electrical data | |||||||||
Operating voltage [V] | 14…30 DC | ||||||||
Min. insulation resistance [MΩ] | 100; (500 V DC) | ||||||||
Protection class | III | ||||||||
Reverse polarity protection | yes | ||||||||
Inputs / outputs | |||||||||
Number of inputs and outputs | Number of analogue outputs: 1 | ||||||||
Outputs | |||||||||
Total number of outputs | 1 | ||||||||
Output signal | analogue signal | ||||||||
Number of analogue outputs | 1 | ||||||||
Analogue current output [mA] | 4…20 | ||||||||
Max. load [Ω] | 550; (Ub = 24 V; (Ub – 13 V) / 20 mA) | ||||||||
Overload protection | yes | ||||||||
Measuring/setting range | |||||||||
Measuring range |
|
||||||||
Analogue start point |
|
||||||||
Analogue end point |
|
||||||||
In steps of |
|
||||||||
Factory setting |
|
||||||||
Accuracy / deviations | |||||||||
Repeatability [% of the span] | < ± 0,1; (with temperature fluctuations < 10 K; Turn down 1:1) | ||||||||
Characteristics deviation [% of the span] | < ± 0,6; (Turn down 1:1 , linearity, incl. hysteresis and repeatability , limit value setting to DIN EN IEC 62828-1) | ||||||||
Linearity deviation [% of the span] | < ± 0,5; (Turn down 1:1) | ||||||||
Hysteresis deviation [% of the span] | < ± 0,1; (Turn down 1:1) | ||||||||
Long-term stability [% of the span] | < ± 0,1; (Turn down 1:1; per year) | ||||||||
Temperature coefficient zero point [% of the span / 10 K] | < ± 0,1; (0…80 °C) | ||||||||
Temperature coefficient span [% of the span / 10 K] | < ± 0,2; (0…80 °C) | ||||||||
Response times | |||||||||
Max. response time analogue output [ms] | 3 | ||||||||
Software / programming | |||||||||
Parameter setting options | zero point; span | ||||||||
Interfaces | |||||||||
Communication interface | EPS | ||||||||
Operating conditions | |||||||||
Ambient temperature [°C] | -25…80 | ||||||||
Storage temperature [°C] | -40…100 | ||||||||
Protection | IP 67 | ||||||||
Tests / approvals | |||||||||
EMC |
|
||||||||
Shock resistance |
|
||||||||
Vibration resistance |
|
||||||||
Mechanical data | |||||||||
Weight [g] | 540 | ||||||||
Materials | stainless steel (1.4404 / 316L); PEI; PBT | ||||||||
Materials (wetted parts) | ceramics (99.9 % Al2O3); stainless steel (1.4435 / 316L); surface characteristics: Ra < 0,4 / Rz 4; PTFE | ||||||||
Min. pressure cycles | 100 million | ||||||||
Process connection | Clamp DN25…DN40 (1…1,5″) DIN 32676 (ISO 2852) | ||||||||
anzeigen-bedienelemente | |||||||||
Remarks | |||||||||
Pack quantity | 1 pcs. | ||||||||
Electrical connection | |||||||||
Connection | Connector: 1 x M12 |