PI009A
Pressure sensor with display PI009A
Product characteristics PI009A | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Output signal | switching signal; analogue signal; (configurable) | ||||||||||
Measuring range |
|
||||||||||
Process connection | threaded connection G 1 external thread sealing cone | ||||||||||
Application | |||||||||||
Special feature | Gold-plated contacts | ||||||||||
Application | food and beverage industry | ||||||||||
Installation | freely rotatable housing 350° | ||||||||||
Media | viscous media and liquids with suspended particles; liquids and gases | ||||||||||
Medium temperature [°C] | -20…60; (when used outside the hazardous area:; Ambient temperature: -25…85 °C; Medium temperature: -25…125 °C / 145 °C < 1h) | ||||||||||
Min. bursting pressure |
|
||||||||||
Pressure rating |
|
||||||||||
Type of pressure | relative pressure; vacuum | ||||||||||
Electrical data |
|||||||||||
Operating voltage [V] | 18…32 DC | ||||||||||
Current consumption [mA] | < 50 | ||||||||||
Protection class | III | ||||||||||
Reverse polarity protection | yes | ||||||||||
Power-on delay time [s] | 0.5 | ||||||||||
Integrated watchdog | yes | ||||||||||
Inputs / outputs | |||||||||||
Number of inputs and outputs | Number of digital outputs: 1; Number of analogue outputs: 1 | ||||||||||
Outputs | |||||||||||
Total number of outputs | 2 | ||||||||||
Output signal | switching signal; analogue signal; (configurable) | ||||||||||
Electrical design | PNP/NPN | ||||||||||
Number of digital outputs | 1 | ||||||||||
Output function | normally open / normally closed; (parameterisable) | ||||||||||
Max. voltage drop switching output DC [V] | 2 | ||||||||||
Permanent current rating of switching output DC [mA] | 250 | ||||||||||
Switching frequency DC [Hz] | 6 | ||||||||||
Number of analogue outputs | 1 | ||||||||||
Analogue current output [mA] | 4…20, invertible; (scalable 1:4) | ||||||||||
Max. load [Ω] | (Ub – 10 V) / 20 mA | ||||||||||
Analogue voltage output [V] | 0…10, invertible; (scalable 1:4) | ||||||||||
Min. load resistance [Ω] | 2000 | ||||||||||
Short-circuit protection | yes | ||||||||||
Type of short-circuit protection | pulsed | ||||||||||
Overload protection | yes | ||||||||||
Measuring/setting range | |||||||||||
Measuring range |
|
||||||||||
Set point SP |
|
||||||||||
Reset point rP |
|
||||||||||
Analogue start point |
|
||||||||||
Analogue end point |
|
||||||||||
In steps of |
|
||||||||||
Accuracy / deviations | |||||||||||
Switch point accuracy [% of the span] | < ± 0,2; (Turn down 1:1) | ||||||||||
Repeatability [% of the span] | < ± 0,1; (with temperature fluctuations < 10 K; Turn down 1:1) | ||||||||||
Characteristics deviation [% of the span] | < ± 0,2; (Turn down 1:1 , linearity, incl. hysteresis and repeatability , limit value setting to DIN EN IEC 62828-1) | ||||||||||
Linearity deviation [% of the span] | < ± 0,15; (Turn down 1:1) | ||||||||||
Hysteresis deviation [% of the span] | < ± 0,15; (Turn down 1:1) | ||||||||||
Long-term stability [% of the span] | < ± 0,1; (Turn down 1:1; per year) | ||||||||||
Temperature coefficient zero point [% of the span / 10 K] | < ± 0,05; (0…70 °C) | ||||||||||
Temperature coefficient span [% of the span / 10 K] | < ± 0,15; (0…70 °C) | ||||||||||
Response times | |||||||||||
Response time [ms] | < 100 | ||||||||||
Damping for the switching output dAP [s] | 0.1…100 | ||||||||||
Damping for the analogue output dAA [s] | 0.1…100 | ||||||||||
Step response time analogue output [ms] | 25 | ||||||||||
Software / programming | |||||||||||
Parameter setting options | hysteresis / window; normally open / normally closed; switching logic; current/voltage output; Damping; adaptation of displayed values; display can be rotated and switched off; Display unit; zero point; span | ||||||||||
Operating conditions |
|||||||||||
Ambient temperature [°C] | -20…60 | ||||||||||
Storage temperature [°C] | -40…100 | ||||||||||
Protection | IP 65 | ||||||||||
Tests / approvals | |||||||||||
ATEX marking | II 3D Ex tc IIIC T90°C Dc X | ||||||||||
II 3G Ex nA IIC T4 Gc X | |||||||||||
EMC |
|
||||||||||
Shock resistance |
|
||||||||||
Vibration resistance |
|
||||||||||
MTTF [years] | 163 | ||||||||||
Mechanical data | |||||||||||
Weight [g] | 513 | ||||||||||
Materials | stainless steel (1.4404 / 316L); PC; PBT; PEI; FKM; PTFE | ||||||||||
Materials (wetted parts) | ceramics (99.9 % Al2O3); stainless steel (1.4435 / 316L); stainless steel (1.4404 / 316L); surface characteristics: Ra < 0,4 / Rz 4; PTFE; EPDM | ||||||||||
Min. pressure cycles | 100 million | ||||||||||
Process connection | threaded connection G 1 external thread sealing cone | ||||||||||
Displays / operating elements | |||||||||||
Display |
|
||||||||||
Display unit | mbar; kPa; psi; inH2O; mWS; % of the span | ||||||||||
Remarks | |||||||||||
Pack quantity | 1 pcs. | ||||||||||
Electrical connection | |||||||||||
Connection | Connector: 1 x M12; Contacts: gold-plated |