PI2602
Flush pressure sensor with display PI2602
Product characteristics PI2602 | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Output signal | switching signal; analogue signal; IO-Link; (configurable) | ||||||||||
Measuring range |
|
||||||||||
Process connection | threaded connection G 1 external thread sealing cone | ||||||||||
Application | |||||||||||
Special feature | Gold-plated contacts | ||||||||||
Application | flush mountable for the food and beverage industry | ||||||||||
Media | viscous media and liquids with suspended particles; liquids and gases | ||||||||||
Conditionally suitable for | use in gases at pressures > 25 bar only on request | ||||||||||
Medium temperature [°C] | -25…125; (145 max. 1h) | ||||||||||
Min. bursting pressure |
|
||||||||||
Pressure rating |
|
||||||||||
Vacuum resistance [mbar] | -1000 | ||||||||||
Type of pressure | relative pressure; vacuum | ||||||||||
No dead space | yes | ||||||||||
Electrical data |
|||||||||||
Min. insulation resistance [MΩ] | 100; (500 V DC) | ||||||||||
Protection class | III | ||||||||||
Reverse polarity protection | yes | ||||||||||
Integrated watchdog | yes | ||||||||||
2-wire | |||||||||||
Operating voltage [V] | 20…32 DC | ||||||||||
Current consumption [mA] | 3.6…21 | ||||||||||
Power-on delay time [s] | 1 | ||||||||||
3-wire | |||||||||||
Operating voltage [V] | 18…32 DC | ||||||||||
Current consumption [mA] | < 45 | ||||||||||
Power-on delay time [s] | 0.5 | ||||||||||
Inputs / outputs | |||||||||||
Number of inputs and outputs | Number of digital outputs: 2; Number of analogue outputs: 1 | ||||||||||
Outputs | |||||||||||
Total number of outputs | 2 | ||||||||||
Output signal | switching signal; analogue signal; IO-Link; (configurable) | ||||||||||
Electrical design | PNP/NPN | ||||||||||
Number of digital outputs | 2 | ||||||||||
Output function | normally open / normally closed; (parameterisable) | ||||||||||
Number of analogue outputs | 1 | ||||||||||
Analogue current output [mA] | 4…20, invertible; (scalable) | ||||||||||
Short-circuit protection | yes | ||||||||||
Type of short-circuit protection | pulsed | ||||||||||
Overload protection | yes | ||||||||||
2-wire | |||||||||||
Max. load [Ω] | 300 | ||||||||||
3-wire | |||||||||||
Max. voltage drop switching output DC [V] | 2 | ||||||||||
Permanent current rating of switching output DC [mA] | 250 | ||||||||||
Switching frequency DC [Hz] | 125 | ||||||||||
Max. load [Ω] | (Ub – 10 V) / 20 mA | ||||||||||
Measuring/setting range | |||||||||||
Measuring range |
|
||||||||||
Set point SP |
|
||||||||||
Reset point rP |
|
||||||||||
Analogue start point |
|
||||||||||
Analogue end point |
|
||||||||||
In steps of |
|
||||||||||
Factory setting |
|
||||||||||
Accuracy / deviations | |||||||||||
Switch point accuracy [% of the span] | < ± 0,5; (Turn down 1:1) | ||||||||||
Repeatability [% of the span] | < ± 0,1; (with temperature fluctuations < 10 K; Turn down 1:1) | ||||||||||
Characteristics deviation [% of the span] | < ± 0,5; (Turn down 1:1 , linearity, incl. hysteresis and repeatability , limit value setting to DIN EN IEC 62828-1) | ||||||||||
Linearity deviation [% of the span] | < ± 0,15; (Turn down 1:1) | ||||||||||
Hysteresis deviation [% of the span] | < ± 0,15; (Turn down 1:1) | ||||||||||
Long-term stability [% of the span] | < ± 0,1; (Turn down 1:1; per year) | ||||||||||
Temperature coefficient zero point [% of the span / 10 K] | < ± 0,2; (0…70 °C) | ||||||||||
Temperature coefficient span [% of the span / 10 K] | < ± 0,2; (0…70 °C) | ||||||||||
Response times | |||||||||||
Damping for the switching output dAP [s] | 0…30 | ||||||||||
Damping for the analogue output dAA [s] | 0.01…99.99 | ||||||||||
2-wire | |||||||||||
Step response time analogue output [ms] | 45 | ||||||||||
3-wire | |||||||||||
Min. response time of switching output (dAP) [ms] | 3 | ||||||||||
Step response time analogue output [ms] | 7 | ||||||||||
Interfaces | |||||||||||
Communication interface | IO-Link | ||||||||||
Transmission type | COM2 (38,4 kBaud) | ||||||||||
IO-Link revision | 1.0 | ||||||||||
Profiles | no profile | ||||||||||
SIO mode | yes | ||||||||||
Required master port type | A | ||||||||||
Process data analogue | 1 | ||||||||||
Process data binary | 2 | ||||||||||
Min. process cycle time [ms] | 2.3 | ||||||||||
Supported DeviceIDs |
|
||||||||||
Operating conditions |
|||||||||||
Ambient temperature [°C] | -25…80 | ||||||||||
Storage temperature [°C] | -40…100 | ||||||||||
Protection | IP 67; IP 68; IP 69K | ||||||||||
Tests / approvals | |||||||||||
EMC |
|
||||||||||
Shock resistance |
|
||||||||||
Vibration resistance |
|
||||||||||
MTTF [years] | 154 | ||||||||||
Note on approval |
|
||||||||||
Mechanical data | |||||||||||
Weight [g] | 374 | ||||||||||
Materials | stainless steel (1.4404 / 316L); FKM; PTFE; PBT; PEI; PFA | ||||||||||
Materials (wetted parts) | ceramics (99.9 % Al2O3); stainless steel (1.4435 / 316L); surface characteristics: Ra < 0,4 / Rz 4; PTFE | ||||||||||
Min. pressure cycles | 100 million | ||||||||||
Process connection | threaded connection G 1 external thread sealing cone | ||||||||||
Displays / operating elements | |||||||||||
Display |
|
||||||||||
Display unit | bar; MPa; psi; % of the span | ||||||||||
Remarks | |||||||||||
Pack quantity | 1 pcs. | ||||||||||
Electrical connection | |||||||||||
Connection | Connector: 1 x M12; Contacts: gold-plated |