Suffix code
+ Length measurement code chart |
Model | code | Min measurement length | Gear ratio | Circumference of wheel | Number of pulse per 1 revolution |
PSC | MA | 1 m | 4 : 1 | 250 mm | 1 pulse |
MB | 1 cm | 4 : 1 | 100 pulse | ||
MC | 1 mm | 2 : 1 | 500 pulse | ||
YA | 1 YARD | 4 : 1 | 228.6 mm (0.25/Yd) |
1 pulse | |
YB | 0.1 YARD | 4 : 1 | 10 pulse | ||
YC | 0.01 YARD | 4 : 1 | 100 pulse |
· Specification
Model | PSC | ||
Electrical specification | Phase difference on output |
Phase difference between the A and B : T/4 ± T/8 (1 cycle of A phase = T) | |
Response speed | 100 K㎐ max. | ||
Rated voltage | 5 – 12 V DC (±5 %), 12 – 24 V DC (±5 %) | ||
Current consumption | Max 70 ㎃ | ||
Connection type | Cable extended type | ||
Control output |
Voltage and open collector | Load voltage : max 30 V/load current : max 30 ㎃/Remaining voltage : max 0.4 V | |
Totem pole | LOW (Load current : max 30 ㎃/Remaining voltage : max 0.4 V) HIGH (Load current : max 10 ㎃/Output voltage : above rated voltage – 1.5 V DC) | ||
Response time | Max 1 μs (Wire length : 1.5 m Iv sink = 30 ㎃) | ||
Mechanical specification |
Starting torque | Max 200 gf·㎝ (19.600 u N·m) | |
Moment of inertia | Max 800 g·㎠ (8X10-6kg·m²) | ||
Permissible shaft loading | Radial : 0.1 ㎜ within, Thrust : 0.2 ㎜ within | ||
Max permissible revolution | 5,000 rpm | ||
Bearing life | 1.2 X 10/ (r/min) : time | ||
Mechanical specification |
Insulation resistance | Min 500 MΩ (Between the terminal and case) | |
Dielectric strength | 500 V AC (For 1 min in 60 ㎐ between the terminal and case) | ||
Vibration resistance | 10 – 55 ㎐ (Period for 1 min), Double amplitude : 1.5 ㎜, for 2 hour each in X, Y and Z directions |
||
Shock resistance | Max 75 G | ||
Ambient temperature | -10 ~ 60 ℃ (No icing allowed), When storing : -25 ~ 85 ℃ | ||
Ambient humidity | 35 ~ 70 % R.H | ||
Wire specification | Number of strips : 5 P, Thickness : Ø 6.0 ㎜, Length : 1.5 m, Shield cable | ||
Weight | Approx. 625 g |