PY9060
Pressure sensor with display PY9060
Product characteristics | |||||||
---|---|---|---|---|---|---|---|
Output signal | switching signal; analogue signal; IO-Link; (configurable) | ||||||
Measuring range |
|
||||||
Process connection | homogeniser connection | ||||||
Application | |||||||
Special feature | Gold-plated contacts | ||||||
Measuring element | diaphragm seal | ||||||
Application | flush mountable for the food and beverage industry | ||||||
Media | liquids and gases | ||||||
Medium temperature [°C] | 5…90; (< 1 h: 145) | ||||||
Min. bursting pressure |
|
||||||
Pressure rating |
|
||||||
Vacuum resistance [mbar] | -1000 | ||||||
Type of pressure | relative pressure | ||||||
Electrical data | |||||||
Operating voltage [V] | 18…30 DC; (according to EN 50178 SELV/PELV) | ||||||
Current consumption [mA] | < 35 | ||||||
Min. insulation resistance [MΩ] | 100; (500 V DC) | ||||||
Protection class | III | ||||||
Reverse polarity protection | yes | ||||||
Power-on delay time [s] | 0.3 | ||||||
Integrated watchdog | yes | ||||||
Inputs / outputs | |||||||
Number of inputs and outputs | Number of digital outputs: 2; Number of analogue outputs: 1 | ||||||
Outputs | |||||||
Total number of outputs | 2 | ||||||
Output signal | switching signal; analogue signal; IO-Link; (configurable) | ||||||
Electrical design | PNP/NPN | ||||||
Number of digital outputs | 2 | ||||||
Output function | normally open / normally closed; (parameterisable) | ||||||
Max. voltage drop switching output DC [V] | 2 | ||||||
Permanent current rating of switching output DC [mA] | 250 | ||||||
Switching frequency DC [Hz] | < 500 | ||||||
Number of analogue outputs | 1 | ||||||
Analogue current output [mA] | 4…20; (scalable 1:5) | ||||||
Max. load [Ω] | 500 | ||||||
Analogue voltage output [V] | 0…10; (scalable 1:5) | ||||||
Min. load resistance [Ω] | 2000 | ||||||
Short-circuit protection | yes | ||||||
Type of short-circuit protection | pulsed | ||||||
Overload protection | yes | ||||||
Measuring/setting range |
|||||||
Measuring range |
|
||||||
Set point SP |
|
||||||
Reset point rP |
|
||||||
Analogue start point |
|
||||||
Analogue end point |
|
||||||
In steps of |
|
||||||
Accuracy / deviations | |||||||
Switch point accuracy [% of the span] | < ± 0,4; (Turn down 1:1) | ||||||
Repeatability [% of the span] | < ± 0,1; (with temperature fluctuations < 10 K; Turn down 1:1) | ||||||
Characteristics deviation [% of the span] | < ± 1; (linearity, incl. hysteresis and repeatability; limit value setting to DIN EN IEC 62828-1) | ||||||
Hysteresis deviation [% of the span] | < ± 0,1; (Turn down 1:1) | ||||||
Long-term stability [% of the span] | < ± 0,05; (Turn down 1:1; per 6 months) | ||||||
Temperature coefficient zero point [% of the span / 10 K] | 0,2; (5…80 °C) | ||||||
Temperature coefficient span [% of the span / 10 K] | 0,2; (5…80 °C) | ||||||
Response times | |||||||
Response time [ms] | < 1.5 | ||||||
Delay time programmable dS, dr [s] | 0…50 | ||||||
Damping for the switching output dAP [s] | 0…4 | ||||||
Damping for the analogue output dAA [s] | 0…4 | ||||||
Max. response time analogue output [ms] | 3 | ||||||
Software / programming | |||||||
Parameter setting options | hysteresis / window; normally open / normally closed; switch-on/switch-off delay; Damping; Display unit; current/voltage output | ||||||
Interfaces | |||||||
Communication interface | IO-Link | ||||||
Transmission type | COM2 (38,4 kBaud) | ||||||
IO-Link revision | 1.1 | ||||||
SDCI standard | IEC 61131-9 | ||||||
Profiles | Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis | ||||||
SIO mode | yes | ||||||
Required master port type | A | ||||||
Process data analogue | 1 | ||||||
Process data binary | 2 | ||||||
Min. process cycle time [ms] | 2.3 | ||||||
Supported DeviceIDs |
|
||||||
Operating conditions |
|||||||
Ambient temperature [°C] | 5…80 | ||||||
Storage temperature [°C] | -40…100 | ||||||
Protection | IP 67 | ||||||
Tests / approvals | |||||||
EMC |
|
||||||
Shock resistance |
|
||||||
Vibration resistance |
|
||||||
MTTF [years] | 143 | ||||||
Mechanical data | |||||||
Weight [g] | 675 | ||||||
Materials | 1.4542 (17-4 PH / 630); stainless steel (1.4404 / 316L); stainless steel (1.4435 / 316L); PBT+PC-GF30; PBT-GF20; PC | ||||||
Materials (wetted parts) | stainless steel (1.4435 / 316L) | ||||||
Min. pressure cycles | 60 million; (at 1.2 times nominal pressure) | ||||||
Process connection | homogeniser connection | ||||||
Displays / operating elements | |||||||
Display |
|
||||||
Remarks | |||||||
Pack quantity | 1 pcs. | ||||||
Electrical connection | |||||||
Connector: 1 x M12; Contacts: gold-plated |